In many cases, the answer is a simple one: the software iSCSI initiator that comes with the operating system, typically loaded as a device driver. Remember that one of the key drivers for iSCSI storage solutions is keeping the costs down. Nothing drives up costs faster than having to to buy dedicated hardware to make the solution work. Using a hardware initator also means that fewer servers will be attached to the iSCSI SAN, which means that the cost can't be amortized across as many systems and lengthens the ROI.
While software iSCSI initiators don't incur an added cost, there is a perception that their performance suffers in comparison with hardware iSCSI initiators. That's because the software initiator has to perform a translation from IP to SCSI and back any time storage data is received over the IP segment.
Requires Membership to View
To gain access to this and all member only content, please provide the following information:
By submitting your registration information to SearchStorageChannel.com you agree to receive email communications from the TechTarget network of sites, and/or third party content providers that have relationships with TechTarget, based on your topic interests and activity, including updates on new content, event notifications, new site launches and market research surveys. Please verify all information and selections above. You may unsubscribe at any time from one or more of the services you have selected by editing your profile, unsubscribing via email or by contacting us here
- Your use of SearchStorageChannel.com is governed by our Terms of Use
- We designed our Privacy Policy to provide you with important disclosures about how we collect and use your registration and other information. We encourage you to read the Privacy Policy, and to use it to help make informed decisions.
- If you reside outside of the United States, by submitting this registration information you consent to having your personal data transferred to and processed in the United States.
Nowadays, most servers have plenty of excess processing power to perform the protocol translation. (In fact, server virtualization now exists because it's rare to find a single application that can consume all the processing power of a host.) And, jumbo-frame-capable products, which lower the load on the processor by adjusting the Ethernet frame size beyond its relatively small (from a storage perspective) default setting, are now much more commonplace than in the past. And configuring jumbo frames is much easier. In an iSCSI network, each frame that the server receives needs to be processed for IP-to-SCSI conversion. The more frames, the more time the server spends processing each frame and the busier the CPU is at that task as opposed to others. Making the frame size larger means that the server CPU will have fewer frames to process.
When do hardware initators make sense to recommend? There are two distinct scenarios. The first and most likely scenario is when your customer wants to boot the physical server from the iSCSI SAN array. Today, this can only be done with a hardware iSCSI initiator. There are valid reasons to recommend this. For example, if the server is being booted from a local hard disk, that local hard disk needs to be protected separately. If everything is booting from the SAN, all the protection and recovery can be focused on the SAN, leveraging its ability to do snapshots and replication to protect all data. Some customers will pay the extra expense for a hardware iSCSI initiator instead of having to manage extra data protection processes. The other use case may be encryption. If iSCSI cards have encryption embedded into them, they could address some of a customer's security concerns.
Most hardware iSCSI initators have processing capabilities on the card to offload the IP to SCSI conversion, which should help address CPU utilization issues as discussed above. In reality, however, we have not seen many situations where software initiators cause an undue amount of additional load. Reaching 75% or more of the potential bandwidth of your iSCSI connection is now realistic with software iSCSI initiators. Hardware-based initiators are generally unnecessary except in situations where booting from the SAN is desirable.
About the author
George Crump is president and founder of Storage Switzerland, an IT analyst firm focused on the storage and virtualization segments. With 25 years of experience designing storage solutions for data centers across the United States, he has seen the birth of such technologies as RAID, NAS and SAN. Prior to founding Storage Switzerland, George was chief technology officer at one of the nation's largest storage integrators, where he was in charge of technology testing, integration and product selection. Find Storage Switzerland's disclosure statement here.
This was first published in March 2010